beautypg.com

Notice – Furuno FAR-2157 User Manual

Page 29

background image

2-5

8. Connect coaxial cable to TB802 on the PCB 03P9435. Fix the shield and conductor as shown

below.

How to fasten coaxial conductor

9. Referring to the illustration above for location, fasten shield (crimp-on lug FV5.5-4 attached) of

signal cable with screw on chassis.

10.Pocess unused wires as follows:

a) Slip shrink tubing onto cores and heat.

b) Bind the wires with a cable tie and pass them through the cable gland on the chassis.

11.Close the cover which protects pcb 03P9436.

12.Seal the cable gland for the signal cable with putty.

NOTICE

Fasten BARE conductor. Do not

use a crimp-on lug, to prevent

increased contact resistance.

Fasten shield by clamp.

Fasten conductor
with screw.

Taping