Fabricating HV cable TYPCY-1.5 and power cable TYPCY-2.5

1. Unfasten the gland nut for the HV cable and remove gasket, flat washers (3 pcs.) and gland

cap. (The gland cap may be discarded.)

2. Fabricate the HV cable as shown below.

How to fabricate HV cable TYPCY-1.5

3. In the order shown in the figure below, pass the gland nut, flat washers (3 pcs.) and gasket onto

the HV cable.

4. As shown in the figure below, fold back the armor onto flat washer (2) and insert remaining

armor through flat washer (3). Cut off the part of the armor that protrudes past the flat washers
(2) and (3).

Passing flat washer, etc. onto HV cable

5. Pass the HV cable through its cable gland and then tighten gland nut.

6. Connect wiring to TB901, referring to the interconnection diagram.

7. Unfasten the gland nut for the power cable and remove gasket, flat washer (3 pcs.) and gland

cap. (The gland cap may be discarded.)

20 mm

5 mm

Sheath

Armor

Vinyl
sheath

600 mm

FV2-4

Conductor

S = 1.50 mm

2

φ = 1.56 mm

Armor

Sheath

SECTIONAL VIEW

(1)

Flat washer

(2) (3)

Cut off armor that
protrudes past washer.

Gasket

HV cable

Gland nut