beautypg.com

FUJITSU MAW3073NC/NP User Manual

Page 98

background image

6-2

C141-E226

Brief test contents of self-diagnostics are as follows.

a. Hardware function test


This test checks the basic operation of the controller section, and contains following test.

RAM (microcode is stored)

Peripheral circuits of microprocessor (MPU)

Memory (RAM)

Data buffer

b. Seek

test


This test checks the positioning operation of the disk drive using several seek modes (2 points
seek, 1 position sequential seek, etc.). The positioning operation is regarded as success when
the seek operation to the target cylinder is completed.

c. Write/read

test


This test checks the write/read function by using the Internal test space of the disk drive.


(1) Initial

self-diagnostics

When power is turned on, the HDD starts initial self-diagnostics. The initial self-diagnostics
checks the basic operations of the hardware functions.

If an error is detected in the initial self-diagnostics, the LED on the drive front panel blinks. In this
status, the HDD posts the CHECK CONDITION status to all I/O operation requests other than the
REQUEST SENSE command. When the CHECK CONDITION status is posted, the initiator
should issue the REQUEST SENSE command. The sense data obtained with the REQUEST
SENSE command details the error information detected with the initial self-diagnostics.

Even if CHECK CONDITION status and sense data are posted, the LED continues blinking. Only
when the power is turned off or re-turned on, this status can be cleared. When this status is
cleared, the HDD executes the initial self-diagnosis again.