beautypg.com

3 environmental specifications – FUJITSU MAW3073NC/NP User Manual

Page 30

background image

2-4

C141-E226

2.1.3 Environmental

specifications

Table 2.3 lists environmental and power requirements.

Table 2.3

Environmental/power requirements

Specification

Item

MAW3300NC/NP MAW3147NC/NP MAW3073NC/NP

Operating

5 to 55°C

Non-operating –40

to

70°C

Transport
(within a week)

–40 to 70°C

DE surface temperature
at operating

5 to 60°C

Temperature
(*1)

Gradient

15°C/h or less

Operating

5 to 95%RH

Non operating

5 to 95%RH

Transport
(within a week)

5 to 95%RH

Relative
humidity

Maximum wet bulb
temperature

29°C (no condensation)

Operating (*3)

0.6 mm (5 to 20 Hz)/9.8 m/s

2

(1 G) (20 to 300 Hz) or less

Non-operating (*4)

3.1 mm (5 to 20 Hz)/49 m/s

2

(5 G) (20 to 300 Hz) or less

Vibration
(*2)

Transport (packaged)

3.1 mm (5 to 20 Hz)/49 m/s

2

(5 G) (20 to 300 Hz) or less

Operating 637.4

m/s

2

(65 G)/2 ms duration

Non-operating 2205

m/s

2

(225 G)/2 ms duration

Shock (*2)

Transport (packaged)

2205 m/s

2

(225 G)/2 ms duration

Operating

–305 to +3,048 m (-1,000 to +10,000 feet)

Altitude

Non-operating

–305 to +12,192 m (-1,000 to +40,000 feet)

Idle

0.6 A ave.

Spin-up

3.0 A (peak within 100

µs)

+12V DC
±5 %

Random
W/R

1.0 A (about 80 IOPS)

Idle

0.46 A ave.

+5V DC
±5 % (*6)

Random
W/R

1.0 A (about 80 IOPS)

Power
requirements
(*5)

Ripple
(+5 V and +12 V)

250 mVp-p or less (*7)

(*1)

For detail condition, see Section 4.1.

(*2)

Vibration applied to the drive is measured at near the mounting screw hole on the frame as much
as possible.

(*3)

At random seek write/read and default on retry setting with log sweep vibration.

(*4)

At power-off state after installation

Vibration displacement should be less than 2.5 mm.

(*5)

Input voltages are specified at the drive connector side, during drive ready state.

This manual is related to the following products: