beautypg.com

Furuno CSH-24F User Manual

Page 46

background image


41

LC fixing position priority

Latitude and Longitude are set to LC with S3 on the DIP switch DP-1.

1. LC-RMA

from

NMEA

2. LC-RMA

from

CI/NMEA

3. <24> from CIF port


Depth priority

Depth is set to CIF/NMEA with S5 on the DIP switch DP-1.

1. SD-DPT from NMEA port

2. SD-DPT from CI/NMEA port

3. SD-DBT from NMEA port

4. SD-DBT from CI/NMEA port

5. <57> from CIF port


Ship’s movement data priority (data from GPS/DR)

Ship’s movement data is set to GPS·DR with S1/S2 on the DIP switch DP-1

1. GP-VTC from NMEA port

2. GP-VTC from CI/NMEA port

3. GP-RMC from NMEA port

4. GP-RMC from CI/NMEA port

5. <48> from CIF port

6. <41> from CIF port


Ship’s movement data priority (data from Current indicator)

Ship’s movement data is set to Current indicator with S1/S2 on the DIP switch DP-1

1. VD-VTG from NMEA port

2. VD-VTG from CI/NMEA port

3. VD-VHW from NMEA port

4. VD-VHW from CI/NMEA port

5. CIF signal <66> from CI/NMEA port

6. <66> from CIF port


Ship’s movement data priority (data from Gyro/Navigation)

Ship’s movement data is set to Gyrocompass/navigation with S1/S2 on the DIP switch

DP-1.

1. GP-VTG from NMEA port

2. GP-VTG from CI/NMEA port

3. GP-RMC from NMEA port

4. GP-RMC from CI/NMEA port

5. LC-VTG

NMEA

port

6. LC-VTG from CI/NMEA port

7. LC-RMA from NMEA port

8. LC-RMA from CI/NMEA port

9. <48> from CIF port

10. <44> from CIF port


Current data (Multi layer) priority

1. VD-CUR from NMEA port

2. VD-CUR from CI/NMEA port

3. CIF signal <76> from CI/NMEA port

4. <76> from CIF port


Current data (single layer) priority

1. VD-VDR from NMEA port

2. VD-VDR from CI/NMEA port

3. CIF signal <56> from CI/NMEA port

4. <56> from CIF port