beautypg.com

Quickspecs, Hp alphaserver gs1280 systems systems – HP GS1280 User Manual

Page 10

background image

1.

2.

1.

2.

3.

4.

Step 3 - CPU Building Block Modules – Mandatory

M=Mandatory
O=Optional

Supported Configurations

CPUs

2

4

6

8

10

12

14 16 18 20 22 24 26 28

30

32

36

40

44

48

52

56

60

64

Dual CPU Modules

1

2

3

4

5

6

7

8 9 10 11 12 13 14

15

16

18

20

22

24

26

28

30

32

GS1280 Model 8

M

O

O

O

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

GS1280 Model 16

M

O

O

O

O

O

O

O -

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

GS1280 Model 32

M

O

O

O

O

O

O

O O O O O O O

O

O

-

-

-

-

-

-

-

-

GS1280 Model 64

-

-

-

-

-

-

-

M -

-

- O -

-

-

O

O

O

O

O

O

O

O

O

Configuration Guidelines

CPU Building Blocks with different clock speeds can co-exist in one system, but must be separated into hard
partitions where the CPUs have the same speed.
CPU Building Block or instant Capacity (iCAP) CPU Building Block Modules type (Tru64 UNIX or OpenVMS) must
match the base system operating system selected in Step 2, or purchase a base operating system upgrade license to
match the license with the CPU Building Block Module.

Full Use CPU Building
Block Modules

AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1300
MHz, Tru64 UNIX SMP License

3X-KN72D-AB

AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1300
MHz, OpenVMS SMP License

3X-KN72D-AC

AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1150
MHz, Tru64 UNIX SMP License

3X-KN72C-AB

AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1150
MHz, OpenVMS SMP License

3X-KN72C-AC

Configuration and Use of instant Capacity (iCAP) CPUs
The instant Capacity (iCAP) program gives HP customers the option to purchase add-on CPU modules at a reduced price
and install those modules in systems ready to activate instantly when needed for extra computational capacity. To use the
iCAP program for AlphaServers:

Order and install iCAP CPU modules along with Full Use CPUs. The total number of Full Use CPU Building Block
Modules plus iCAP CPU Building Bock Modules must adhere to the limits outlined above for GS1280 systems.
Use the iCAP software (supplied with the iCAP CPU Module) to set iCAP CPUs inactive. As long as the total number
of active CPUs does not exceed the number of licensed CPUs owned for the system, the owner may choose which
CPUs to designate as iCAP.
Inactive iCAP CPUs cannot include the primary CPU, CPUs responsible for hardware interrupts, CPUs being used by
an application when configuring iCAP, or a CPU connected to an I/O Building Block Drawer.
Activate the iCAP CPUs for First Use when extra capacity is needed, and then promptly purchase the iCAP
Enablement (Right-to-Use).

iCAP CPU Building Block Module + iCAP Enablement = Full Use CPU Building Block Module

QuickSpecs

HP AlphaServer GS1280 Systems

Systems

DA - 11921 Worldwide — Version 24 — July 23, 2007