Warning – Forno 30 Inch Single Electric Wall Oven Installation Guide User Manual

Page 8

background image

7

WARNING

Electrical Shock Hazard

The electrical power to the oven branch circuit must be shut off while

line connections are being made.
Do not use an extension cord with this appliance.
Electrical ground is required on this appliance. The free end of the green

wire (the ground wire) must be connected to a suitable ground. This

wire must remain grounded to the oven.
If cold water pipe is interrupted by plastic, non metallic gaskets, union

connections or other insulating materials, DO NOT use for grounding.
DO NOT ground to a gas pipe.
DO NOT have a fuse in the NEUTRAL or GROUNDING circuit. A fuse in

the NEUTRAL or GROUNDING circuit could result in an electrical shock.
Check with a qualified electrician if you are in doubt as to whether the

appliance is properly grounded.
Failure to do so could result in death, fire or electric shock.

Electrical Connection
To properly install your oven, you must determine the type of electrical connection

you will be using and follow the instructions provided for it here.

Oven must be connected to the proper electrical voltage and frequency as

specified on the model/serial number rating plate. The model/serial number

rating plate is located under the control panel on single ovens and under the

control panel on the upper oven cavity on double ovens. All models are dual

rated, and designed to be connected to either 120/208V or 120/240V AC, 60Hz,

3-wire or 4-wire, single-phase power supply.

Style

Voltage and

Frequency

Amps

Circuit Required

Single Oven

240V, 60 Hz

20.0A

25 Amp Circuit

208V, 60 Hz

17.4A

20 Amp Circuit

Double Oven

240V, 60 Hz

35.4A

40 Amp Circuit

208V, 60 Hz

30.7A

35 Amp Circuit

Install a suitable conduit box (not furnished). An appropriately sized, UL conduit

connector must be used to correctly attach the conduit to the junction box.
IMPORTANT: Local Codes may vary; installation electrical connections and

grounding must comply with all applicable local codes.