beautypg.com

Do not attempt to lift this product unassisted, Take care – some panel edges are sharp, Warning – Fisher & Paykel Series 9 Professional Series 30 Inch Double Convection Smart Electric Wall Oven Installation Guide User Manual

Page 2: Important! save these instructions

background image

2

WARNING!

To avoid hazard, follow these instructions carefully before installing or using this appliance.

z

Save these instructions for the local inspectors use.

z

Please make this information available to the person installing the appliance — doing so

could reduce your installation costs.

z

This oven is to be installed and connected to the electricity supply only by an

authorized person.

z

If the installation requires alterations to the domestic electrical system, call a qualified

electrician. The electrician should also check that the socket cable section is suitable

for the electricity drawn by the oven.

z

The oven must be grounded.

z

Installation must comply with your local building and electricity regulations.

z

This appliance must be installed and connected to the mains power supply only by a

suitably qualified person according to these installation instructions and in compliance

with any applicable local building and electricity regulations. Failure to install the

appliance correctly could invalidate any warranty or liability claims.

z

If the power supply cable is damaged, it must be replaced by the manufacturer,

its service agent or similarly qualified person in order to avoid a hazard.

z

A circuit breaker is recommended.

z

Do not use adaptors, reducers or branching devices to connect the oven to the mains

electricity supply, as they can cause overheating and burning.

z

Ensure the cavity is completely sealed with no gaps. This is to ensure the oven cooling

system functions correctly.

z

The appliance must not be installed behind a decorative door in order to avoid overheating.

Electrical requirements

z

Connect oven with copper wire only.

z

Do not cut the conduit.

z

A U.L. listed conduit connector must be provided at the junction box.

z

Do not ground to a gas pipe.

z

Do not have a fuse in the grounding or neutral circuit.

z

Fuse both sides of the line.

z

A time delay fuse or circuit breaker is recommended. If using a time delay fuse,

then fuse both sides of the line.

z

Flexible armored cable from the appliance should be connected directly to the junction box.

z

Connect directly to the fused disconnect (or circuit breaker box) through flexible,

armored or non-metallic sheathed, copper cable (with grounding wire).

z

If codes permit and a separate grounding wire is used, it is recommended that

a qualified electrician determine that the grounding path and wire gauge are in

accordance with local codes.

SAFETY AND WARNINGS

!

WARNING!

Electric Shock Hazard

Failure to follow this advice may result in

electric shock or death.

• Before carrying out any work on the electrical

section of the appliance, it must be disconnected

from the mains electricity supply.

• Connection to a good earth wiring system is

absolutely essential and mandatory.

• Alterations to the domestic wiring system must

only be made by a qualified electrician.

!

WARNING!

Fire Hazard

Failure to follow this advice may result in

overheating, burning, and injury.

• Do not use adapters, reducers, or branching

devices to connect this appliance to the mains

power supply.

!

WARNING!

409 lb

186 kg

242 lb

110 kg

Very Heavy

Failure to follow this advice may result in

serious injury.

• Do not attempt to lift this product unassisted.

IMPORTANT!

SAVE THESE INSTRUCTIONS

The models shown in this installation guide may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country,

please go to our website www.fisherpaykel.com or contact your local Fisher & Paykel dealer.

!

WARNING!

Cut Hazard

Failure to use caution could result in injury.

• Take care – some panel edges are sharp.