Self Tests
Running Parameter Tests
The luminaire is capable of running self tests by using the
TEST
menu functions. For complete details
and values for each test refer to
When running tests on multiple luminaires, a DMX termination connector is required at the last
luminaire in the link. (Refer to
for more information regarding the construction of this
connector.).
Figure 4-5: Test Setup
To run tests:
Step 1. Press [ESC].
Step 2. Press [Up] / [Down] arrows until
Test
appears. Press [OK].
Step 3. Use [Up] / [Down] arrows to select a parameter to test. Refer to
for a complete list of test parameters which can be chosen.
Step 4. Press [OK] to run test.
Step 5. Press [ESC] to stop test at any time.
Note:
Connected luminaires may not respond on the first action (may delay) of the master luminaire.
Movement Disable
The
Movement
option allows pan and tilt to be disabled so that the luminaire can be placed in any
position for testing without movement occurring. In order to regain full control of the luminaire,
Movement
will need to be enabled after testing.
Note:
When using the
Movement
option, pan and tilt will be disabled for all the luminaires that are
linked.
*DMX terminator required for last fixture on DMX line.
Data In
Termination*
Data Thru
AC In
AC In
AC In
Master luminaire containing
software version to download
Luminaire 1
requiring
Luminaire 2
requiring
Data Thru
update
update