Power and data cabling requirements, Power – VARI-LITE VL6000 Beam User Manual
Page 32

VARI
❋
LITE - VL6000 B
EAM
L
UMINAIRE
U
SER
’
S
M
ANUAL
14
27 April 2017
02.9708.0002
Power and Data Cabling Requirements
Power
The luminaire requires standard AC power distribution from 200-240 VAC, 50/60 Hz. Current
required depends on the AC supply voltage and product model. Refer to
for all models covered in this manual.
Note:
The mating Neutrik® powerCON® True1 connector is supplied, however, you will need to
purchase or construct a cable appropriate for your application. Available power input cables is found in
“Replacement Items/Accessories” on page 9
Figure 2-1: Power Connector
Depending on the application, the luminaire’s AC input cable may require a different connector. If
required, install a new connector meeting your requirements using the following wire color code
reference:
AC Power Input
3-Pole Neutrik® powerCON® True1 for AC Input Power
Neutrik® powerCON® True1
AC Input Connector
Wire*
Connection
Green/Yellow
AC Ground
Blue
AC Neutral
Brown
AC Line
* International (Harmonized) Standard