Photogenic Professional Lighting Matrix MCD400R Monolight with Ion Inverter, Beauty Dish, Grid, and Stand User Manual
Page 11

P a g e
11 | 16
Default setting is b5 (means the block time of pre-flash is 10 milliseconds).
Value b 1 2 3 4 5 6 7 8 9
Time (milliseconds) 2 4 6 8 10 12 14 16 18
8.0 Audible Beep Settings
Press the AUDIO Button
B
(Fig. 5) to provide an “audible ready confirmation”. A short beep will indicate
that the unit is ready to fire.
NOTE: When AUDIO Button
B
(Fig. 5) is OFF, the modeling lamp will momentarily turn off when the flash
is fired and will come back on when ready.
9.0 Flash Output
The flash power output is variable over a 6 f-stops range from 1/32 to full in 1/10 f-stop increments using
the Flash Power Control
H
(Fig.5). The power is displayed in an easy to use decimal form where each
whole number represents 1 f-stop. The control has a minimum setting of 1.0 and a maximum setting of
6.0. Pressing the button
H
(Fig.5) will change the value by 0.1 f-stop (giving a total of 51 values). For
example, if the current value shown is 5.6, then to reduce the power by 1 f-stop just reduce the setting to
4.6. The following table shows the whole decimal numbers and equivalent fractional power ratio:
Display power
Fractional equivalent
6.0
1(FULL)
5.0
1/2
4.0
1/4
3.0
1/8
2.0
1/16
1.0
1/32 (MIN)
10.0 Changing the Flash Tube
10.1 Discharge the Flash Unit
The charge in the flash unit must be discharged before removing the flash tube. Contact with high voltage
may result in injury or death if instructions are not followed.
Figure 18A
Figure 18B