CobraMig 260 Owner's Manual - Page 24

FLOW CHART

1. Check TORCH POT at plug connector

a. Testing the poteniometer - "W"
Clocked
. - Using Ohm Meter to check

resistance across pin "D" (wiper) and pin

"C" of Torch plug. Should vary from 0 to
5k ohm while turning pot. - Using Ohm Meter
to check resistance across pin "D"

(wiper) and pin "G" of Torch plug.

Should vary from 0 to 5k ohm while

turning pot.

5

5

SYMPTOM

NO WIRE FEED AT TORCH, FEEDER OPERATING PROPERLY

PROBLEM AREA

COBRA MAIN BOARD, TORCH POT OR TORCH MOTOR

b. Testing the poteniometer - "S"
Clocked
. - Using Ohm Meter to
check resistance across pin "D"
(wiper) and pin "C" of Torch plug.
Should vary from 0 to 5k ohm while
turning pot.- Using Ohm Meter to
check resistance across pin "D"
(wiper) and pin "A" of Torch plug.
Should vary from 0 to 5k ohm while
turning pot.

2. Check TORCH MOTOR

a. Unplug the Torch from the front panel.
b. Using the Ohm Meter, Check the
resistance across pin "A" and pin "B"
(motor leads) of Torch plug. The resis-
tance should be about 5 to 10 ohms.
c. If open of short circuit exists, then check
motor leads and motor for additional prob-
lems.

NO

YES

START

NO

YES

CHECK TORCH MOTOR

(SEE NOTE 2 BELOW)

YES

NO

YES

CABLE IS BROKEN

OR

TORCH POT IS DEFECTIVE

NO

NOTES:

WAS METER READING OK ?

CABLE IS BROKEN

OR

TORCH MOTOR IS DEFECTIVE

COBRA MAIN BOARD

IS DEFECTIVE

WAS METER READING OK ?

CHECK TORCH POT

(SEE NOTE 1 BELOW)

SYSTEM OK

IS THE TORCH WORKING

OK NOW ?

GO TO FLOW CHART #3
COBRA I MAIN BOARD,
F1 FUSE IS BLOWN

CHECK FOR LOOSE CABLES

AT COBRA FRONT PANEL AND

MAIN P.C. BOARD

IS COBRA MAIN

BOARD F1 FUSE OK?