beautypg.com

Flow chart – MK Products CobraMig 260 PS/Feeder User Manual

Page 28

background image

CobraMig 260 Owner's Manual - Page 22

FLOW CHART

NOTE :

MOTOR CHECK

a. Remove the amphenol connector from the cabinet.

b. Using an OHM meter, check the resistance across pins "A" and "B" (motor leads)

on torch amphenol. The resistance across the motor should be between 5 and 10 ohms.

c. If an open circuit or short circuit condition exists, check the motor leads and motor

independently.

3

3

PROBLEM AREA

COBRA: MAIN BOARD OR TORCH MOTOR

SYMPTOM

COBRA: MAIN BOARD, F1 FUSE IS BLOWN

YES

NO

UNPLUG TORCH AMPHENOL

FROM COBRA FRONT PANEL

NO

COBRA I MAIN P.C. BOARD IS

DEFECTIVE

MOTOR LEADS ARE SHORTED

OR MOTOR IS DEFECTIVE

YES

JUMPER "E" AND "F" ON EITHER

OF THE COBRA FRONT PANEL

AMPHENOL CONNECTORS

GO TO FLOW CHART #4
COBRA I MAIN BOARD, F1 AND
F3 ARE OK, BUT WIRE FEED
AND TORCH NOT OPERATIVE

START

IS COBRA MAIN

BOARD F1 FUSE OK?

IS COBRA MAIN

BOARD F1 FUSE OK?