beautypg.com

Flow chart – MK Products CobraMig 260 PS/Feeder User Manual

Page 27

background image

CobraMig 260 Owner's Manual - Page 21

FLOW CHART

NOTE :

The 115VAC on Cobra I Main P.C. Board is protected by

Fuse F3. If F3 continually blows, unplug J4 (Brake Solenoid), J7
(Slave Motor) from the P.C. Board. Replace the fuse and retrigger. If
fuse does not blow, isolate the problem by plugging in J4 and J7 one
at a time until the fuse blows.

Resistance Check :

a) Slave Motor

J7-6 to J7-1 = 150 ohm

J7-4 to J7-2 = 150 ohm

b) Brake Solenoid

J4-1 to J4-2 = 80 ohm

2

2

PROBLEM AREA

COBRA: MAIN BOARD, SLAVE MOTOR OR BRAKE SOLENOID

SYMPTOM

F3 FUSE ON COBRA I IS BLOWN WHEN TORCH IS TRIGGERED

START

GO TO FLOW CHART # 3
COBRA MAIN BOARD, F1 FUSE IS BLOWN

YES

PLUG IN J4

RE-TRIGGER TORCH

NO

NO

YES

PLUG IN J7

RE-TRIGGER TORCH

NO

YES

F3 FUSE BLOWN

COBRA MAIN BOARD

RE-TRIGGER TORCH

UNPLUG CONNECTORS
J4, BRAKE SOLENOID
J7, SLAVE MOTOR

IS COBRA MAIN BOARD

F3 FUSE OK ?

IS COBRA I MAIN BOARD

F3 FUSE OK ?

SLAVE MOTOR IS OK

IS COBRA MAIN BOARD

F3 FUSE OK ?

BRAKE SOLENOID IS

DEFECTIVE

BRAKE SOLENOID IS OK

SLAVE MOTOR IS

DEFECTIVE