3-4. Bandwidth Management


Function name:

Bandwidth Management

Function description:

Bandwidth Management function is used to set up the limit of Ingress and Egress
bandwidth for each port.

Note:

Each port of the switch owns 16KB packet buffer. The packet buffer size will be reduced
when the bandwidth rate limitation is enabled, which may cause that jumbo frame cannot
be forwarded.

Please avoid enabling jumbo frame and bandwidth rating functions at the same time

.

Fig. 3-16


Parameter description:

Port Number:

Choose the port that you would like this function to work on it. Valid range of the
port is 1~8.

All Traffic for Ingress Rate Limiting(Policing):

Set up the limit of Ingress bandwidth for the port you choose. Incoming traffic will be
discarded if the rate exceeds the value you set up in Data Rate field. Pause frames are
also generated if flow control is enabled. The format of the packet limits to unicast,
broadcast and multicast. Valid range is 0~1000.