MICROSENS 8 Port Gigabit Ethernet Switch

User’s Manual

52

Mode:

Set the speed and duplex of the port. In speed, if the media is 1Gbps fiber, it is always
1000Mbps and the duplex is full only. If the media is TP, the Speed/Duplex is comprised
of the combination of speed mode, 10/100/1000Mbps, and duplex mode, full duplex
and half duplex. The following table summarized the function the media supports.

Media type

NWay

Speed

Duplex

1000M TP

ON/OFF

10/100/1000M

Full for all, Half for 10/100

1000M Fiber

ON/OFF

1000M

Full

In Auto-negotiation mode, no default value. In Forced mode, default value depends
on your setting.

Flow Control:

There are two modes to choose in flow control, including Enable and Disable. If flow
control is set Enable, both parties can send PAUSE frame to the transmitting device(s)
if the receiving port is too busy to handle. When it is set Disable, there will be no
flow control in the port. It drops the packet if too much to handle.

Default: Enable.

Wait State:

For more details about this parameter please refer to section 3-2-1.

Default: Disable.