CAUTION: Panels on a cable segment from the AI-512 MUST be daisy-chained from
one panel to another. DO NOT Tee or Wye cable runs, as the panel communication WILL
NOT operate reliably.

Maximum Cable Length:
Each of the two communication cables attached to the AI-512 can be extended up to 800 feet as
long as the daisy-chained connection scheme is maintained. The last panel in the string must have
termination turned on, see setup section for details on termination.

Maximum number of panels:
For each of the two cable segments attached to the AI-512, no more than 1 amp of load current is
available.
To calculate the maximum number of panels, see the chart below:

Part Number

Description

Current Draw

90-03-6103

LHS 1P

0.10

90-03-6104

LHS 3P

0.10

90-03-6106

LHS 6P

0.12

90-03-6108

LHS 12P

0.16

90-03-6110

LHS 3P/3F w/Master

0.15

90-03-6112

LHS 6P/6F w/Master

0.18

90-03-6114

LHS 1F w/Master

0.05

90-03-6115

LHS 3F w/Master

0.05

90-03-6116

LHS 6F w/Master

0.06

90-03-6117

LHS 12F w/Master

0.08

90-03-6101

LHS Lockout

0.05