CAUTION: Panels on a cable segment from the AI-512 MUST be daisy-chained from
one panel to another. DO NOT Tee or Wye cable runs, as the panel communication WILL
NOT operate reliably.
Maximum Cable Length:
Each of the two communication cables attached to the AI-512 can be extended up to 800 feet as
long as the daisy-chained connection scheme is maintained. The last panel in the string must have
termination turned on, see setup section for details on termination.
Maximum number of panels:
For each of the two cable segments attached to the AI-512, no more than 1 amp of load current is
available.
To calculate the maximum number of panels, see the chart below:
Part Number
Description
Current Draw
90-03-6103
LHS 1P
0.10
90-03-6104
LHS 3P
0.10
90-03-6106
LHS 6P
0.12
90-03-6108
LHS 12P
0.16
90-03-6110
LHS 3P/3F w/Master
0.15
90-03-6112
LHS 6P/6F w/Master
0.18
90-03-6114
LHS 1F w/Master
0.05
90-03-6115
LHS 3F w/Master
0.05
90-03-6116
LHS 6F w/Master
0.06
90-03-6117
LHS 12F w/Master
0.08
90-03-6101
LHS Lockout
0.05
4