Leprecon AI-512 User Manual
Page 36
?
The 'Title' field allows a meaningful name to be created for each trigger.
?
Clearing the 'enable' field will disable the trigger, without deleting the data.
?
'Action' describes the effect on the playback – On, Off or Toggle. The toggle mode turns
off a playback that is On, and turns On a playback that was Off.
?
'Room' and 'Playback' fields are used to select the playback that will be triggered.
For DMX triggers specifically, the following fields are used:
?
Channel – this is the DMX IN channel that is monitored for change.
?
Low DMX is the lower limit of the range.
?
High DMX is the upper limit of the range.
Low and High DMX values are needed since the incoming DMX may be rapidly changing. If
only a single DMX value is specified, there is a chance that the specific value will be present for
only an instant, and could be missed by the AI-512 software.
36