ifm electronic RM9000 User Manual
Page 23

UK
CANopen encoder
23
7.5 Device-profile-specific objects from 6000h to 9FFFF
Index S-Idx Name
Type,
access
default value
Description
6000
Operating
parameters
u16, rw
1h
The object sets the counting direction,
the diagnostic function and the scaling
function�
Note: The counting direction is always
seen looking at the shaft� With clockwise
direction of the shaft (CW) the counting
direction is increasing�
Scaling function:
Using the scaling function the position value provided can be adapted to the requirements of
the application via the software� The objects 6001 and 6002 of the device profile are scaling
parameters� When the scaling bit has been set to zero, scaling is switched off�
Bit structure
Bit
15
14
13
12
11���4 3
2
1
0
Description
MS
MS
MS
MS
R
MD
SFC CD
CS
Abbreviations:
MS = manufacturer-specific function (not available)
R = reserved
MD = measurement direction (not available)
SFC = scaling function (0 = off, 1 = on)
CD = commissioning diagnostic control (not available)
CS = counting direction 0 = CW (clockwise); 1 = CCW (counter-clockwise)
6001
0
Measuring
units per
revolution
u32, rw
see
type label
Setting steps per revolution
6002
0
Total
measuring
range in
measuring
units
u32, rw
see
type label
Setting the total resolution of the
measuring range
6003
0
Preset value
u32, rw
0
Setting the preset value for the encoder
6004
0
Position value
u32,
romap
-
The object gets the position value
6030
Speed value
If the max� possible value is exceeded,
the value stops there� The user can use
the object 3010 (32 bits)�
0h
Number of sub
indices
u8, ro
1h
1h
Speed value
channel 1
integer
16, romap
-