2 supported diagnostic messages, 1 extended diagnostic header, 2 memory error – ifm electronic RN3001 User Manual
Page 25: 3 operating status, 4 encoder type, 5 singleturn resolution
UK
Encoder with Profibus interface
25
11.2 Supported diagnostic messages
The individual diagnostic inputs are described in detail below�
11.2.1 Extended diagnostic header
Diagnostic byte 7 contains the length of the extended diagnosis (including the
diagnostic header)�
11.2.2 Memory error
Via bit 4 in diagnostic by 8 it is indicated if a memory error has occurred�
In this case memory error means that the EEPROM of the encoder does no longer
function reliably and non-volatile storage (e�g� of the zero point shift) is no longer
ensured�
Bit
Definition
0
1
4
Memory error
(Fault in
EEPROM)
No
Yes
11.2.3 Operating status
The operating parameters set via parameter setting can be enquired via diagnostic
byte 9�
Bit
Definition
0
1
0
Rotational direction
CW
CCW
1
Class 2 functionality
Off
On
2
Diagnosis routine
Off
On
3
Scaling function
Off
On
11.2.4 Encoder type
The design of the encoder can be enquired via diagnostic byte 10�
Byte 10
Definition
0
Singleturn encoder
1
Multiturn encoder
11.2.5 Singleturn resolution
The physical resolution per revolution of the encoder is stored in the diagnostic
bytes 11���14�