14
10.1 Parameters
The manufacturer-specific parameters are described below� The parameters to the
encoder profile (also supported) are described in chapter 9�
10.1.1 Activation of the manufacturer-specific parameters
The manufacturer-specific parameter byte 26 is activated via bit 6 in octet 9�
The manufacturer-specific bytes 27���39 are activated in byte 26�
Octet 9 bit 6
Octet 26
0
Deactivated
1
Activated
Octet 26 bit 7
Octet 27...29
0
Deactivated
1
Activated
10.1.2 Requested measuring steps
The device can be programmed with the [Desired measuring units] parameter so
that any number of measuring steps referred to
– one revolution
– the entire measuring range
– any part of the measuring range
can be implemented�
Octet
10
11
12
13
Bit
31���24
23���16
15���8
7���0
Data
2
31
to 2
2
4
2
23
to 2
16
2
15
to 2
8
2
7
to 2
0
Required number of measuring steps