Interspace Industries TheatreCue 16 Way V4 System - 16 Outstations User Manual
Page 8

Designed and created by:-
Built By
16 Channel Master Station
(Continued)
Master station’s rear panel
2
1
Go and Standby buttons
Eavesdrop Outstations
The Go and Standby buttons light brightly in response to a
Go or Standby cue. They are driven by data returned from
the Outstations.
They are not just a local indication that a button has been
pressed.
The illuminated
This is known as positive monitoring.
Go and Standby buttons on the Master
Station light dim once an Outstation is connected and has
performed a lamp test. These 2 buttons are used to send
cues to a Cue Light Outstation.
2
1
On any channel, set only one Outstation to Normal Mode.
This Outstation will send return monitoring to the Master
station for driving the Go and Standby lamps
All additional Outstations assigned to that same channel
must be set to Eavesdrop Mode.
They can however, send Call signals. (see the following
page)
For more details on Eavesdrop Mode see the section on
Multiple Outstations per channel (page 18).
These additional Outstations respond to commands from
the Master Station but send no return monitoring.
2
1
08.
Parallel XLR
connectors for
Outstations
Power.
36V DC 1.9A
Parallel Expansion Ports
for PC Interface and
the linking of Masters
Master Mode Switch.
Used when 2 Masters
are connected
(this feature coming soon)