Master station configuration editor – Interspace Industries TheatreCue 16 Way V4 System - 16 Outstations User Manual
Page 43

Designed and created by:-
Built By
Relay A
Relay B
Momentary
Latched
Momentary
Latched
Cue Light Mode
Momentary
Latched
Latched
Momentary
Cue Light Mode
The 5 Relay Modes
Controlled by
Standby button
Controlled by
Go button
43.
Each Relay must be assigned to one of 5 modes.
Select a Relay Mode from these 5 buttons
When any of these buttons are pressed, two buttons will
illuminate yellow lamps to indicate the selected option.
The green buttons indicate the status of the selected
mode for each of the 16 channels. When a green button is
illuminated, that channel is assigned to the selected mode.
Pressing a green button assigns that Relay to the selected
mode. Once assigned to a particular mode, that channel
cannot be deselected by pressing its green button a second
time. To deselect a Relay from a particular mode, just
assign it to the required mode and that action will deselect it
from all other modes.
Relay options (grey buttons)
Relay Mode
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Power
5 modes for each Relay
Options for Relay’s Cue Light Mode
More Relay Options
6
Assign Relay #12 to A:momentary B:Latch mode.
Start the Configuration Editor
Select Page 2
Select A:momentary B:Latch mode
Press green button for channel 12
Save to the ShowTime file
Save to User file 1-4 (optional)
Exit the Configuration Editor
Example:
Change mode for Relay #12
7
Master Station Configuration Editor
Relay Outstation options
1
2
3
1
4
5
1
8
Momentary: Relay operates only while the button is pressed.
Latching:
Press the button to set (turn on) the Relay.
Press it again to reset (turn off) the Relay.
1
2
3
4
5
(continued)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Power
Theatre Cue Light
Master QLM16i2 Mk4
www.interspaceind.com
Innovation by:-
Built By:-
4
Relay
Options
Edit
Channel
Sensor
Options
Safe when
open
Unsafe
flashes
No
EOL
All lamps
enabled
S/by flash
on Master
S/by flash
on Outstn
S/by
latches
Go
times out
Go
flashes
Go
latches
Go & S/by
interlocked
Call lamp
enabled
Call lamp
flashes
All lamps
enabled
Edit all
16 ch.
Open
Save
Relay & Sensor.
Page 2
Select
page
Exit
A: Latch
B: Latch
A: Mom
B: Latch
A: Latch
B: Mom
Cue Light
Mode
A: Mom
B: Mom
5
Installer
defaults
User 1
User 2
User 3
User 4
Show
Time
Factory
default red
Factory
default yel
6
7
8