This example shows how a theatre might be permanently
wired using a mix of daisy chain and star wiring.
Backbone cable segments in green are wired with a thicker
cable as these have a larger number of outlets attached to
them.
The Master Station unit could be located at XLR point #8
during rehearsals. The cable between the patch panel and
points #8 would have to carry 100% of the Outstation load,
hence the thicker cable.
Small venues, or those using 8 or less Outstations, could be
cabled entirely in 24 AWG.
Typical cables would be:-
24 AWG - Belden 9841
20 AWG - Belden 9463
Theatre wiring example.
1: Fly Gallery
2: Stage traps
3: Stage
4: Orchestra Pit
Patch
Panel
Stage
Stalls
Pit
Balcony
3
3
3
2
2
2
3
2
2
2
3
1
1
1
4
4
4
6
5
6
6
7
7
5
5
7
1
7
8
8
5: Balcony
6: Lighting & spots
7: Doors
8: Sound & Rehearsal desk.
24 AWG cable
20 AWG cable
Permanently wired Cue Light XLRs
1
1
1
3
3
3
A wiring example
30.
Outstation Cables
(Continued)