Master station configuration editor – Interspace Industries TheatreCue 16 Way V4 System - 16 Outstations User Manual
Page 45

Designed and created by:-
Built By
45.
The Sensor Outstation has 4 options ,3 of which are
programmable from the Outstation’s front panel.
When an option is changed from the Outstation, the change
is sent to the Master Station and saved in the Master
Station’s ShowTime file for recall next time the system is
turned on.
To save ShowTime file changes to one of the 4 User files,
follow the steps in the example below.
Unsafe lamp Flashes
No End-of-Line resistors
All lamps enabled
Safe when open
when open
Flashes
No resistors
Enabled
Steady
2 EOL resistors
Off
Safe when closed
Sensor Outstation options
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
www.LeonAudio.com.au
Cue Light
Master
QLM16 Mk4
Power
1
Factory
Default
User Selectable
Option
Options
Sensor options
( this feature coming soon- not yet available)
Master Station Configuration Editor
Start the Configuration Editor.
The Editor opens with the ShowTime file already loaded.
Save the ShowTime file to User file 1-4.
Exit the Configuration Editor.
Example:
Saving changes made to the ShowTime file
5
Select an option to edit by using the yellow buttons
The button will light to indicate the selection.
Toggle all 16 channels at once by using the Edit all 16 ch
button
The All lamps enabled option can only be edited by using
the Master Station Configuration Editor. This option blanks
all lamps on the Sensor Outstation which is useful when the
Sensor Outstation needs to hide from public view.
When the lamps are disabled, pressing the Grey Enable
button on the Outstation will momentarily light the
Outstation’s lamps so that its operation can be monitored or
its mode changed.
Edit that option on a channel by channel basis using the
Green buttons (Green button lit = option active)
1
Start the Configuration Editor
Select Page 2
Select No EOL option
Press the green button for channel 4 to deselect the
No EOL option.
(Green button lit = no EOL resistors)
(Green button not lit = 2 EOL resistors)
Save to the ShowTime file
Save to User file 1-4 (optional)
Exit the Configuration Editor
Example:
(set Sensor #4 to use 2 End-of-Line resistors)
4
5
6
2
3
(continued)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Power
Theatre Cue Light
Master QLM16i2 Mk4
www.interspaceind.com
Innovation by:-
Built By:-
Relay
Options
Sensor
Options
Edit
Channel
Open
Edit all
16 ch.
Exit
Select
page
Relay & Sensor.
Page 2
Save
S/by flash
on Master
S/by flash
on Outstn
S/by
latches
Go
times out
Go
flashes
Go
latches
Go & S/by
interlocked
Call lamp
enabled
Call lamp
flashes
All lamps
enabled
A: Latch
B: Latch
A: Mom
B: Latch
A: Latch
B: Mom
Cue Light
Mode
A: Mom
B: Mom
Safe when
open
Unsafe
flashes
All lamps
enabled
Installer
defaults
User 1
User 2
User 3
User 4
Show
Time
Factory
default red
Factory
default yel
No
EOL
1
4
6
2
3