38. On the terminal side of the green wire,

strip back the insulation 5/16”.

Insert the wire into the smaller side of the

connector, make sure the wire is properly

seated and crimp the connector using an

insulated connector crimping tool.

11.

39. Apply heat evenly around the length of the

tubing (including the crimp area) from the center

out to the ends until the tubing fully recovers

and the adhesive flows. During the heating

process, separate the two wires in the larger

end of the connector to allow the adhesive to

flow in between the wires.

40. Remove from the heat and let cool.

37. Method A (for method B, skip to step 41)

Cut the green wire that connects to pin D4

roughly 1-1/2” away from the terminal.

Strip back the insulation 5/8” on the harness

side of the green wire and also the orange fan

harness wire and insert the two wires into the

larger side of the supplied crimp connector (PN

DC-940010). Make sure that both wires are

properly seated and crimp the connector using

an insulated connector crimping tool.