Maintenance – Glow-worm Ultracom2 cxi User Manual
Page 44
0020112601_02 - 10/12 - Glow-worm
- 42 -
MAINTENANCE
18.4 Servicing
i
If the annual check of combustion CO2, CO/CO2 ratio
checks did not require adjustment and the inspections
described in "Preliminaries" were satisfactory then it
will not be necessary to complete a full service.
All routine servicing requirements can be achieved by the
removal of the front panel.
• Position the control box into the service position.
• Before commencing with a service or replacement of parts,
isolate the boiler from the electrical and gas supplies.
18.4.1
Service interval record
• Refer to the service interval record located on the inside
back pages of this document.
18.5 Silencer
24cxi / 30cxi
A
B
C
2
1
3
Key
1 Silencer retaining screw
2 fixed silencer
3 Removable silencer
• Remove the silencer retaining screws (1) and remove the
silencer (3).
• Clean the interior of the silencer with a dry cloth if necessary,
taking care not to damage the internal foam.
• Repeat the operation in reverse order to replace the silencer.
35cxi
A
3
2
1
Key
1 fixed silencer
2 Silencer retaining clip
3 Removable silencer
• Unclip and remove the silencer (3).
• Clean the interior of the silencer with a dry cloth if necessary,
taking care not to damage the internal foam.
• Repeat the operation in reverse order to replace the silencer.
18.6 Expansion vessel
1
2
Key
1 Expansion vessel
2 Expansion vessel pressure inlet