0020112601_02 - 10/12 - Glow-worm

- 20 -

INSTALLATION

9.2.3

Multiple boiler chimney flue

Ø 60/100 mm (C43 type installation)

b

The flue connecting from the appliance to

the flue system must be supplied from the

manufacturer of the boiler.

b

C43 flue systems must not be a 'pressurised

system' but act under natural draught principles

b

C43 type flue systems must have their

own condensate drain fitted and not allow

condensate to mix into other appliances

L

3

2

1

5

4

B

A

Key

1 Pressure balancing system

2 Air-inlet pipe

3 Collector pipe

4 boiler

5 Inspection hatch

A final storey

b Ground floor

Type

Max length (L)

Ø 60/100

10 m

Each time an additional 90° bend is necessary (or 2 at 45°), the

length (L) must be reduced by 1 m.

Model

24cxi

30cxi

35cxi

Exhaust mass rate (g/s)
At min thermal load (40°C/30°C)

2.4

2.9

4.1

At max thermal load (80°C/60°C)

8.3

11.3

13.8

Model

24cxi

30cxi

35cxi

Exhaust temperature (°C)
At min thermal load (40°C/30°C)

45

37

41

At max thermal load (80°C/60°C)

65.7

63.4

71.4

10 Remove the front panel

24

V

230

V

A

A

B

1

2

Key

1 front panel

2 front panel retaining screw

• Undo the two screws (2) on the underside of the front panel

and remove the front panel (1).

11 Electrical connections

e

Incorrect installation can cause electric shock or

appliance damage. The electrical connection of

the appliance must be made only by a qualified

engineer.

The appliance must be connected directly to an accessible,

fixed, switched, electrical outlet.

The external wiring must be earthed, with correct polarity and in

accordance with current standards.

The manufacturer declines any responsibility for damages to

persons or others caused by the incorrect installation of the

appliance earthing. This includes failure to comply with current

standards.

Electrical components have been tested to meet the equivalent

requirements of the BEAB.