Installation – Glow-worm Ultracom2 cxi User Manual
Page 28
0020112601_02 - 10/12 - Glow-worm
- 26 -
INSTALLATION
12.3 filling DHW Circuit
• Open the various hot water taps to fill the DHW circuit.
12.4 filling the Condensate Trap
A
B
C
1
1
2
Key
1 filling trap
2 Condensate trap
• Fill the trap 3/4 full with water (1).
• Activate the Heating and Domestic Hot Water functions.
• Run the appliance for at least 15 minutes, with a heating
temperature set to greater than or equal to 50°C (not
applicable for an installation with underfloor heating).
• Vent air from each radiator again until the water flows
normally, then close the vents.
• If you have difficulties in removing the air, launch the air-
removal programs in the heating circuit (see the chapter
("Technical settings for the appliance and list of parameters").
• Make sure that the pressure indicator shows a value of 0.8
bars; otherwise, fill the appliance again.
12.5 Initial lighting
12.5.1
Control
i
The combustion for this appliance has been
checked, adjusted and preset at the factory for
operation on natural gas (G20) as defined on the
appliance data label.
No measurement of the combustion is necessary.
Should the appliance require to be converted to LPG
gas ensure you follow the gas conversion section
before lighting the boiler.
• Check that the appliance has been installed in accordance
with the instructions.
• Check the integrity of the flue system and flue seals.
• Check the integrity of the appliance combustion circuit and
relevant seals.
• Check that all internal/external controls are calling for heat.
• Check that the gas service isolation is open.
• To adapt the appliance to another type of gas, see chapter
"LPG conversion".
12.5.2
Adjusting the temperature
3
2
1
6
5
4
Key
1 Domestic hot water temperature control buttons
2 Display
3 Reset button
4 On/Off button
5 Central heating temperature control button
6 Mode selection button
• Light the appliance by following the procedure below.
• Select the "Heating + domestic hot water" function by
pressing the “Mode” button repeatedly to scroll through your
options until are shown.
The appliance will enter a self checking routine, then the fan
will start and the ignition sequence commence. The boiler, if
necessary, will automatically repeat the ignition sequence a
further 4 times.
If the burner fails to ignite “F28” will be displayed, initially, this
may be due to air in the gas supply line. Press the reset button.
Do not use the reset button to purge the installation - never
press reset more than 3 times.
• Press the central heating water temperature button and
the factory setting temperature will be displayed.
• Press or buttons to adjust.
• Press the hot water temperature button and the factory
setting temperature will be displayed.
• Press or buttons to adjust.
• Open a hot water tap, the display will indicate the domestic
hot water temperature.
• Check that hot water is available at all taps, then close.