beautypg.com

Dunkirk DWB Series User Manual

Page 29

background image

Hot water tank exclusion (economy)

Hot water tank temperature maintaining/heating can be

excluded by the user. If excluded, domestic hot water will

not be delivered.

The hot water tank can be deactivated by the user (ECO

mode) by pressing the ECO/COMFORT button (detail 7 -

control panel display). In ECO mode the display activates

the ECO symbol (detail 12 - on control panel display). To

activate COMFORT mode, press the ECO/COMFORT button

(detail 7 - on control panel display) again.

Sliding temperature

• When the optional external probe is installed, the boiler

control system operates with “Sliding Temperature”.

In this mode, the temperature of the heating system is

controlled according to the outside weather conditions,

in order to ensure high comfort and energy saving

throughout the year.

• As the outside temperature increases the system

delivery temperature decreases according to a specifi c

“compensation curve”.

• With Sliding Temperature adjustment, the temperature

set with the heating buttons (details 3 and 4 on control

panel display) become the maximum system delivery

temperature.

• Manufacture recommends setting the maximum value

to allow system adjustment throughout its useful

working range.

• Boiler must be adjusted at time of installation by

qualifi ed service agent. Adjustments can be made by

user to improve comfort.

Compensation curve and curve offset

Press the button (see item 6 on the control panel display)

for 5 seconds once to display the actual compensation

curve, which can be modifi ed with the DHW buttons (see

items 1 and 2 on the control panel display).

Adjust the required curve from 1 to 10 according to the

characteristic.

By setting the curve to 0, sliding temperature adjustment is

disabled.

Compensation curve

|||

||

||

||

|||

||||||

|||

||||

|

Press the heating buttons (see items 3 and 4 on the control

panel display) to access parallel curve offset modifi able

with the DHW buttons (see items 1 and 2 on the control

panel display).

Parallel curve shift

|||

||

||

||

|||

||||||

|||

||||

|

10 - OPERATING INSTRUCTIONS

29