3.2.7 CONFIGURATION: HEADER LABEL.

1. Begin with the ENTER light OFF.
2. Turn the thumbwheel switch to position 6.
3. Press the ENTER switch. The ENTER light flashes.
4. Enter the decimal-ASCII code for the label, 2 digits/character. The
maximum number of characters is 30.

The ENTER light flashes before the 1st digit.

The ENTER light is ON before the 2nd digit.

5. Enter two zeros (0, 0) to end the data entry.
6. The ENTER light turns off.




------------------ ENTER HEADER LABEL -----------------



FLASH ON FLASH (Enter Light)


Begin Header Entry 6 (Thumbwheel Switch)


CHAR 1 X X
CHAR 2 X X
.
.
CHAR N 0 0 END OF HEADER ENTRY


REMEMBER:

Return the thumbwheel switch to the correct mode position after configuration