2.5.1 PRINT WEIGHT.
Print the weight on the scale in the form:
WEIGHT 12345 LB
2.5.2 PRINT WEIGHTS WITH GROSS, AND TARE LABELS
.
The Print Switch prints the weight on the scale in the form:
GROSS 12345 LB
The Aux Switch prints the weight on the scale in the form:
TARE 2000 LB
2.5.3 GROSS, TARE, NET PRINTING.
This feature provides gross, tare, and net printing in 2 weighments.
The Aux Switch instructs the printer store the weight on the scale into
the tare register. The printer cycles to signal that tare weight is
read.
The Print Switch causes the printer to print the
GROSS, TARE, and NET
weights.
2.5.4 PRINT AND TOTAL.
This feature provides a total register for summing weighments.
The Print Switch prints the weight on the scale. The printer adds the
weight to the total register.
The Aux Switch prints the total.
Press the Aux Switch twice within 10 seconds to clear the total
register. The print head will cycle at the end of 10 seconds to signal
that the printer is ready for new commands.