Read-cycle reset/keep-alive, Read, Cycle reset/keep-alive – ThingMagic Autonomous Configuration Tool User Manual
Page 26: Message example
Processing Data from the Reader
Autonomous Configuration Tool v1.0 User Guide
26
Read-Cycle Reset/Keep-Alive
The Read-Cycle Reset/Keep-Alive message are sent once per second and always have a
non-0x0000 Status Word, with 0x0400 indicating normal.
Table 7:
Read-Cycle Reset Packet Format
Message Example
A sample Read-cycle Reset/Keep-alive message indicating normal:
A sample Read-cycle Reset/Keep-alive message indicating over-temperature, RF being
throttled temporarily:
Field
Value
Description
Header (Hdr)
0xFF
Defines the start of the packet.
Data Length (Len)
0x00
Cycle reset contains no additional data after the status code.
OpCode
0x22
Autonomous reader message
Status Word
[2 bytes]
• 0x0400 indicates a read-cycle start message...also acts
as a heartbeat when the reader is reading but no tags are
in the field.
• 0x0504 indicates the maximum temperature of the
module (85C as reported by
) has been exceeded and reading has been
temporarily throttled.
• Other non-0x0000 fault code. See readerʼs Hardware
Guide for list of fault-codes.
CRC-16
Checksum
[2 bytes]
See
.
FF
00
22
04
00
84
E0
SOH
Length
OpCode
Status Word
CRC
FF
00
22
05
04
85
E4
SOH
Length
OpCode
Status Word
CRC