beautypg.com

5installation instructions, Indoor unit installation – Pridiom Solar Series Installation Manual User Manual

Page 6

background image

5

INSTALLATION INSTRUCTIONS

Fi g.4

Wall

Indoor

Outdoor

F ig.6

Fig.5

Indoor unit installation

2. Drill a hole in the wall

1. Fit the Installation Plate
1. Fit the installation plate horizontally

on structural parts of the wall with
spaces around the installation plate.

2. If the wall is m ade of brick, concrete

or the like, drill eight (8) 5m m diam eter
holes in the wall.Insert Clip anchor for
appropr iate mounting screws.

3. Fit the installation plate on the wall

with eight (8) type

“A” screws.

1. Determine hole positions according

to the diagramdetailed in Fig.5. Dr ill
one (1) hole (

65mm) slanting slightly

to outdoor side.

2. Always use wall hole conduit when

drilling metal grid, metal plate or the like.

φ

C orre ct or ient ation
o f Ins talla tion Plat e

Note:
Fit the Installation Plate and drill
holes in the wall according to the
wall structure and corresponding
mounting points on the installation
plate. The installation plate is different
according to the models.

(Dimensions are in

“mm” unless

otherwise stated)

900

Right rear side

refrigerant

pipe hole

65

φ

Installation plate

Indoor unit outline

Left rear side

refrigerant
pipe hole

65

φ

150mm or more to ceiling

120mm or

more to wall

120mm or

more to wall

9 0

150

PDF created with pdfFactory Pro trial version