INSTALLATION INSTRUCTIONS

Selecting installation place

Select an installation location which is rigid and strong enough to support or hold the unit, and select a

location for easy maintenance. Read completely, then follow step by step.

Indoor unit

Do not expose the indoor unit to heat or steam.
Select a place where there are no obstacles in front
or around the unit.
Make sure that condensation drainage can be
conveniently routed away.
Do not install near a doorway.
Ensure the spaces indicated by arrows from the
wall ceiling or other obstac les.
A place where noise prevention is taken into consideration.
A place 1m or m ore to TV or radio instrument.
A place where air circulation in the room is good.
There should not be any direct sunlight. Otherwise, the sun
will fade the plastic cabinet and affect its appearance. If
unavoidable, sunlight prevention should be taken into consideration.

Outdoor unit

If an awning is built over the outdoor unit to prevent
dir ect sunlight or rain expos ure, make sure that heat
radiation from the condenser is not restricted.
Keep the spaces indicated by arrows from wall or
other obstacles.
Do not place animals and plants in the path of the
air inlet or outlet.
Take the air conditioner weight into account and
select a place where noise, vibration and hot air
dis charged will not be an issue.
Do not install in a place full of machine oil or sulfide
gas such as hot-spring resort.
Do not install in a saline place such as c oast.
Do not install in a place where there are high frequency
machines such as wireless equipment, welding
machine or medical facility.

If the outdoor unit is installed on a roof structure, be sure to level the unit.
Ensure the roof structure and anchoring method are adequate for the unit location.
Consult local c odes regarding rooftop mounting.

Rooftop installation:

Level gauge
Sc rewdriver
Electric drill,Hole core drill (

65

φ

mm)

Flaring tool set
Specified torque wrenches: 1.8kgf.m,

4.2kgf.m, 5.5kgf.m, 6.6kgf.m

(different depending on model No.)
Spanner (half union)

Tools needed for installation:

Hexagonal wrench (4mm)
Gas-leak detector
Vacuum pump
Gauge manifold
Users manual
Thermometer
Multimeter
Pipe cutter
Measuring tape

F ig.1

Fig.2

Front