Auger drive & lockout – Wheatheart R Series Augers User Manual
Page 23
W
HEATHEART
- R S
ERIES
A
UGERS
5. O
PERATION
R8-36, R8-41, R8-46, R8-51, R10-36, R10-41, & R10-51
5.3. A
UGER
D
RIVE
& L
OCKOUT
30758 R1
23
Figure 5.3 Belt Engaging Lever & Engine
5.3. AUGER DRIVE & LOCKOUT
Correct operation of the Wheatheart auger requires pre-inspection of the drive
system, operator knowledge on how to shut down the system, and a general
monitoring of the system during operation.
G
AS
E
NGINE
DRIVE SYSTEM
Before starting the motor, ensure that:
1. The gas tank is properly closed.
2. The belt release is disengaged so that the belts are released from the motor
pulley.
3. The area surrounding the auger is properly ventilated.
4. Pulley shields are in place and secure.
LOCKOUT
1. Shut down and lock out power source.
2. For engines with a rope or crank start, remove the spark plug wire or the
spark plug. For engines with an electric start, remove the ignition key, the
spark plug wire, or the spark plug.
E
LECTRIC
M
OTOR
DRIVE SYSTEM
Before starting the motor, ensure that:
1. The motor is properly grounded.
2. The belt release is disengaged so that belts are released from motor pulley.
3. Pulley shields are in place and secure.
LOCKOUT
1. The electric motor should be equipped with a main power disconnect switch
capable of being locked in the off position only. The switch should be in the