beautypg.com

Kramer Electronics VS-41HDCP User Manual

Page 30

background image

VS-41HDCP - Kramer Protocol

27

27

Command Name

Short Cmd

Command Type

Permission

NAME?

Common (Ethernet)

End User

Get machine (DNS) name

Syntax

#NAME?

Response

~nn@NAME␠machine_name␍␊

Parameters

machine_name

– String of u

p to 14 alpha-numeric chars (can include hyphen, not in

beginning or end).

Notes

The machine name is not the same as the model name. The machine name is used to
identify a specific machine or a network in use (with DNS feature on).

Command Name

Short Cmd

Command Type

Permission

AV

Switch

End User

Switch Audio and Video

Syntax

#AV

in>out, in>out,…␍

Response

~nn@AV

in>out, in>out,…␍␊

Parameters

In - input number or '0' to disconnect output

'

>

' = Connection character between in and out parameters

out = Output number or '*' for all outputs

Command Name

Short Cmd

Command Type

Permission

VID

V

Switch

End User

Switch Video

Syntax

#VID

in>out, in>out,…␍

Response

~nn@VIDin>out ␍␊ ~nn@VIDin>out ␍␊

Parameters

In - input number or '0' to disconnect output

'

>

' = Connection character between in and out parameters

out = Output number or '*' for all outputs

Notes

When AFV switching mode is active, this command also switches Audio and the unit replies
with command ~AV.