Third party control is supported via two physical interfaces:
1. RS-232 serial port
2. Ethernet port
The AMD P Series amplifiers provide third party communications when the amplifier is placed in the
power saving mode.
RS-232 PORT INFORMATION
Baud
Rate
Data
Bits
Parity
Stop
Bits
Duplex
Flow
Control
19,200
8
None
1
Full
None
RS-232 Packet Structure
The serial protocol is an ASCII protocol. All characters in the string are ASCII characters.
Binary values ranging between hexadecimal 00 and FF are transmitted as two ASCII characters.
All command strings start with the % character and end with a carriage return (shown as
in this document) and are equal to the single ASCII value of 13 decimal (0x0D hex).
ETHERNET PORT INFORMATION
Port
Speed
Protocol
Receive
Port
Transmit
Port
Duplex
10/100Mbps
UDP
11223
11224
Full
Ethernet Packet Structure
Ethernet messages are constructed using a simple header and data structure:
The message header is either a Master (3rd party) or Slave (AMD P series) Header.
Messages from the third party system:
Messages from the AMD P series amplifier: