Media Technology Systems ION8.8 User Manual
Page 11

Page 11 of 26
Jul‐09
Figure 3-2: Bypass OID value
Router (OUT)
OID value
OFF/MUTE
0
IN 1 to OUT
1
IN 2 to OUT
2
IN 3 to OUT
3
IN 4 to OUT
4
…
…
Inn to OUT
n
Figure 3-3: Router OID value
Simple timing values are defined by using the sample rate divided by the block size. The
Hold Time shown in
Figure 3-4 is calculated by the algorithm HT = (
Desired Time in
Seconds
)*48000/16, where the sample rate is usually 48kHz and the block size is 16.
Hold time
OID value
(S)
Sample/Block
10
30000
1
3000
0.1
300
Figure 3-4: Hold time OID
Other
dB
values
(eg,
Threshold,
Depth
and
Knee)
are
calculated
by
the
algorithm
(
Target dB value)
*2^23. See
Figure 3-5 for example values.
Threshold/
OID value =
Depth/Knee (dB)
dB x 2^23
24
201326592
12
100663296
0
0
‐12
‐100663296
‐24
‐201326592
‐36
‐301989888
‐48
‐402653184
‐64
‐536870912
‐100
‐838860800
Figure 3-5: Depth, Threshold & Knee OID values
Other values are calculated from the Sample rate. For example the Frequency of a sine
wave generator is calculated by F = 2*(
Desired Frequency in Hertz
)/48000 and then the
result multiplied by 2^31 to get a 2 bit value – see
Figure 3-6 below