8.1. Technical characteristics
Measuring range (*):
0.05
70m (0.2in229ft)
Resolution: 0.001m
(0.001ft)
Accuracy (@10m):
1.5mm (**)
Tilt measuring range:
65° (side <10°)
Laser pointer:
635nm, Class II, <1mW
Display:
LCD, 5 digits with
backlight
Power supply:
2x1.5V type AA LR06
Duration:
up to 8000 measurements
Operating temperature:
0°C
40°C
Storage temperature:
-10°
60°C
Auto power off:
30s (laser), 3min (iDM70)
Size (LxWxH):
135 x 53 x 30mm
Weight (batteries
included):
160g
Mechanical protection:
IP54
Bluetooth:
3.0 EDR, range 10m
(*) Measuring range and accuracy depend on the correct reflection of the laser beam
from the surface of the object to the instrument's sensor and on the brightness of the
environment in which tests are performed.
(**) Under favourable conditions (optimum object surface, room temperature). Under
unfavourable conditions (intense sunshine, poor reflective properties of the object,
high variations in temperature) the resolution in measurements >10m may be higher
by ±0.15mm/m (±0.0018in/ft)
8.2. Reference standards
EMC:
IEC/EN61326-1 :2006
IEC/EN61326-2-2 :2006
IEC/EN61326-1 :2005
IEC/EN61326-2-2 :2005
2004/108/EC EMC directive
Laser :
IEC/EN60825-1