Brine Tank(s)

Inlet

Bypass Valve

Brine Tank(s)

Outlet

Isolation Valves

Flex Connectors

MAV Valve

H200 Twin/Triplex/Fourplex Installation Top-Mount -
First-in, Last-Out Piping Arrangement.

H200 Single Installation - Side Mount

Brine Tank

Inlet

Outlet

Bypass Valve

Isolation

Valves

Sidemount

Adapter Base

Brine Line

1" MNPT

2” FNPT Inlet &

2.5” Victaulic

2” FNPT Outlet &

2.5” Victaulic

Internal Meter

See NOTE Figure 5

Figure 4

Figure 5

NOTE:

System connections to the tank must accommodate longitudinal movement between side, top and bot-

tom openings, flexibility in piping or flex connectors are recommended.

Red colored piping, fittings, and connectors are for reference only and are not included. Must be fur-

nished by others.

Union type connectors are recommended on the inlet and outlet connections.

1" Brine Line must be hard-piped, secured and supported for proper operation. CPVC or Schedule 80 PVC

recommended.

Shut-Off Valve

Shut-Off Valve

Shut-Off Valve

MAV = Motorized Alternating Valve.