beautypg.com

Hellenbrand H200HF Series User Manual

Page 13

background image

RATED CAPACITY

FLOW RATES (gpm)

RESIN

LOW SALT

MEDIUM SALT

HIGH SALT

BKW

MODEL

CU.FT.

GRAINS/LBS

GRAINS/LBS

GRAINS/LBS

15 PSI

25 PSI

GPM

H200HF-300-24-3

10

190,000/60

280,000/100

320,000/150

120

170

12

H200HF-300-30-3

10

190,000/60

280,000/100

320,000/150

175

225

20

H200HF-450-30-3

15

285,000/90

420,000/150

480,000/225

158

212

20

H200HF-450-36-3

15

285,000/90

420,000/150

480,000/225

200

278

30

H200HF-600-3

20

380,000/120

560,000/200

640,000/300

189

257

30

H200HF-750-3

25

475,000/150

700,000/250

800,000/375

212

280

40

H200F-900-3

30

570,000/180

840,000/300

960,000/450

200

268

50

H200F-1200-3

40

760,000/240

1,120,000/400

1,280,000/600

213

280

70

H200HF-1200-4

40

760,000/240 1,120,000/400

1,280,000/600

310

445

70

H200HF-1500-3

50

950,000/300 1,400,000/500

1,600,000/750

225

307

90

H200HF-1500-4

50

950,000/300 1,400,000/500

1,600,000/750

340

495

90

H200HF-1950-3

65

1,235,000/390 1,820,000/650

2,080,000/975

235

325

110

H200HF-1950-4

65

1,235,000/390 1,820,000/650

2,080,000/975

445

650

110

1. H200HF-300-24-34 through H200HF-1200-4 are shown with fiberglass mineral tanks. All of these are also available with steel tanks.

2. H200HF-1500-3 through H200HF-1950-4 are available with steel tanks.

OPERATING CONDITIONS

1. Water Pressure 30 - 100 psi.

2. Water temperature is not to exceed 110°F and the unit cannot be subject to freezing conditions. Consult factory for higher water temperature

applications.

3. Limit of 2 ppm of Ferrous Iron. Add 3 grains per gallon of hardness for each ppm of iron present.

4. Flex connectors and vacuum breakers are required when using the PolyGlass Composite mineral tanks.

5. Backwash flow rates are calculated at 4 gpm per sq. ft. of bed area and rounded off based on 50ºF water temperature.

6. Refer to Hellenbrand Bulletin 2050 “Flow Rates and Soft Water Quality (Hardness Leakage) if your application requires that levels of hardness

leakage do not exceed “x”.

All dimensions ±1” and are subject to change without

notice. Use as reference only.

Call factory for optional tank & dimensional configurations.

Product Improvement designs are subject to change

without notice.

H200HF Physical Specifications

H200HF Capacity Ratings

H200HF Series Side Mount Dimensions-Fiberglass Tanks

HELLENBRAND, INC.

(800) 626-1417

www.hellenbrand.com

BRINE TANK

APPROXIMATE

PIPE SIZE MINERAL TANK

SIZE

SALT STORAGE SHIPPING WEIGHT

MODEL

(INCHES)

(INCHES)

(INCHES)

( LBS)

SINGLE

TWIN

H200HF-300-24-3

3

24 X 72

24 X 50

670

1,200

2,300

H200HF-300-30-3

3

30 X 72

24 X 50

670

1,400

2,700

H200HF-450-30-3

3

30 X 72

30 X 50

1,110

1,700

3,300

H200HF-450-36-3

3

36 X 72

30 X 50

1,110

1,900

3,700

H200HF-600-3

3

36 X 72

39 X 48

1,640

2,100

4,100

H200HF-750-3

3

42 X 72

42 X 60

2,580

2,900

5,600

H200HF-900-3

3

42 X 72

50 X 60

4,130

3,350

6,400

H200HF-1200-3

3

48 X 72

50 X 60

4,130

3,850

7,500

H200HF-1200-4

4

48 X72

50 X 60

4,130

–––

–––

H200HF-1500-3

3

54 X 72*

60 X 64

4,000

–––

–––

H200HF-1500-4

4

54 X 72*

60 X 64

4,000

–––

–––

H200HF-1950-3

3

60 X 72*

72 X 54

4,800

–––

–––

H200HF-1950-4

4

60 X 72*

72 X 54

4,800

–––

–––

Mineral tank sizes shown are with polyglass tanks. (*denotes steel tanks)

H200HF-300 92.8 17 85.5 -- 24x72 24x50

H200HF-300-30 95.6 17 85.5 -- 30x72 24x50

H200HF-450 95.6 17 85.5 -- 30x72 30x50

H200HF-600 96.3 17 85.5 -- 36x72 39x48

H200HF-750 101.9 17 85.5 -- 42x72 42x60

H200HF-900 101.9 17 85.5 -- 42x72 50x60

H200HF-1200 100.9 17 85.5 -- 48x72 50x60

SYSTEM OUTLET INLET

DRAIN

MINERAL

BRINE

MODEL

HEIGHT HEIGHTS HEIGHTS HEIGHTS TANK

TANK

73-047

3/13-LBRY

HELLENBRAND WARRANTY

Go to www.hellenbrand.com for warranty details.