RATED CAPACITY
FLOW RATES (gpm)
RESIN
LOW SALT
MEDIUM SALT
HIGH SALT
BKW
MODEL
CU.FT.
GRAINS/LBS
GRAINS/LBS
GRAINS/LBS
15 PSI
25 PSI
GPM
H200HF-300-24-3
10
190,000/60
280,000/100
320,000/150
120
170
12
H200HF-300-30-3
10
190,000/60
280,000/100
320,000/150
175
225
20
H200HF-450-30-3
15
285,000/90
420,000/150
480,000/225
158
212
20
H200HF-450-36-3
15
285,000/90
420,000/150
480,000/225
200
278
30
H200HF-600-3
20
380,000/120
560,000/200
640,000/300
189
257
30
H200HF-750-3
25
475,000/150
700,000/250
800,000/375
212
280
40
H200F-900-3
30
570,000/180
840,000/300
960,000/450
200
268
50
H200F-1200-3
40
760,000/240
1,120,000/400
1,280,000/600
213
280
70
H200HF-1200-4
40
760,000/240 1,120,000/400
1,280,000/600
310
445
70
H200HF-1500-3
50
950,000/300 1,400,000/500
1,600,000/750
225
307
90
H200HF-1500-4
50
950,000/300 1,400,000/500
1,600,000/750
340
495
90
H200HF-1950-3
65
1,235,000/390 1,820,000/650
2,080,000/975
235
325
110
H200HF-1950-4
65
1,235,000/390 1,820,000/650
2,080,000/975
445
650
110
1. H200HF-300-24-34 through H200HF-1200-4 are shown with fiberglass mineral tanks. All of these are also available with steel tanks.
2. H200HF-1500-3 through H200HF-1950-4 are available with steel tanks.
OPERATING CONDITIONS
1. Water Pressure 30 - 100 psi.
2. Water temperature is not to exceed 110°F and the unit cannot be subject to freezing conditions. Consult factory for higher water temperature
applications.
3. Limit of 2 ppm of Ferrous Iron. Add 3 grains per gallon of hardness for each ppm of iron present.
4. Flex connectors and vacuum breakers are required when using the PolyGlass Composite mineral tanks.
5. Backwash flow rates are calculated at 4 gpm per sq. ft. of bed area and rounded off based on 50ºF water temperature.
6. Refer to Hellenbrand Bulletin 2050 “Flow Rates and Soft Water Quality (Hardness Leakage) if your application requires that levels of hardness
leakage do not exceed “x”.
All dimensions ±1” and are subject to change without
notice. Use as reference only.
Call factory for optional tank & dimensional configurations.
Product Improvement designs are subject to change
without notice.
H200HF Physical Specifications
H200HF Capacity Ratings
H200HF Series Side Mount Dimensions-Fiberglass Tanks
HELLENBRAND, INC.
(800) 626-1417
www.hellenbrand.com
BRINE TANK
APPROXIMATE
PIPE SIZE MINERAL TANK
SIZE
SALT STORAGE SHIPPING WEIGHT
MODEL
(INCHES)
(INCHES)
(INCHES)
( LBS)
SINGLE
TWIN
H200HF-300-24-3
3
24 X 72
24 X 50
670
1,200
2,300
H200HF-300-30-3
3
30 X 72
24 X 50
670
1,400
2,700
H200HF-450-30-3
3
30 X 72
30 X 50
1,110
1,700
3,300
H200HF-450-36-3
3
36 X 72
30 X 50
1,110
1,900
3,700
H200HF-600-3
3
36 X 72
39 X 48
1,640
2,100
4,100
H200HF-750-3
3
42 X 72
42 X 60
2,580
2,900
5,600
H200HF-900-3
3
42 X 72
50 X 60
4,130
3,350
6,400
H200HF-1200-3
3
48 X 72
50 X 60
4,130
3,850
7,500
H200HF-1200-4
4
48 X72
50 X 60
4,130
–––
–––
H200HF-1500-3
3
54 X 72*
60 X 64
4,000
–––
–––
H200HF-1500-4
4
54 X 72*
60 X 64
4,000
–––
–––
H200HF-1950-3
3
60 X 72*
72 X 54
4,800
–––
–––
H200HF-1950-4
4
60 X 72*
72 X 54
4,800
–––
–––
Mineral tank sizes shown are with polyglass tanks. (*denotes steel tanks)
H200HF-300 92.8 17 85.5 -- 24x72 24x50
H200HF-300-30 95.6 17 85.5 -- 30x72 24x50
H200HF-450 95.6 17 85.5 -- 30x72 30x50
H200HF-600 96.3 17 85.5 -- 36x72 39x48
H200HF-750 101.9 17 85.5 -- 42x72 42x60
H200HF-900 101.9 17 85.5 -- 42x72 50x60
H200HF-1200 100.9 17 85.5 -- 48x72 50x60
SYSTEM OUTLET INLET
DRAIN
MINERAL
BRINE
MODEL
HEIGHT HEIGHTS HEIGHTS HEIGHTS TANK
TANK
73-047
3/13-LBRY
HELLENBRAND WARRANTY