3. SCREW CALIBRATION

Screw calibration by means of a torque wrench only.

Screw 44 and 57 of the exploded view, should be greased before being tightened by

means of a torque wrench.

Description

Exploded View Position

(From Owner’s Manual)

Fastening Torque

(Ft. Lbs.)

Fastening Torque

(Nm)

Cover fastening screws

19

7.4

10

Oil discharge plug

11

29.5

40

Lifting bracket fastening screw

17

73.8

100

Conrod caps fastening screw

18

28

38*

Plunger fastening

28

14.8

20

Choke

31

7.4

10

Support fastening screw

44

11

15****

Head fastening screw

56

59

80**

Liner fastening screw

57

25.8

35***

Hydraulic motor flange screw

59

29.5

40

* The conrod caps fastening screws must be tighteded respecting the phases indicated in “Point D”

of page 6

** The head fastening screws must be tightened respecting the phases and the order indicated in fig. 45

*** The liner fastening screws must be tightened respecting the phases and the order indicated in fig. 45

****The support fastening screws must be tightened in a single step, respecting the order indicated

in fig. 44