beautypg.com

SUPER MICRO Computer MIIC-203 User Manual

Page 43

background image

44

Mid Level Response: /XCC0000[CR]

Low Level Command:/X dc dCcDCcdCcdCcDCcDCcDCcdCc DCAc

dCcdCcdCcdCcdCcdCcdCcDCc DCAcdCcdCcdCcdCcdCcdCcDCcdCc DCAc
dCcdCcdCcdCcdCcdCcdCcDCc DCAc dCD[CR]
Low Level Response: /XCC0000[CR]

Master read three bytes from slave address 0x4F. First two bytes are acknowledged

by master.

Command: /X S ~4f Rrr P [CR]
Response: /XCCA~xx~xx~xx[CR]

‘(xx = 00...FF)

Master transmit a Write WCR command to a Xicor X9241 at slave address 0x50.

WCR data is 0x00.

Command: /X S ~50 ~a0 ~00 P [CR]
Response: /XCCAAA[CR]

Master transmit a Write WCR command to a Xicor X9241 at slave address 0x50.

WCR data is 0x3f.

Command: /X S ~50 ~a0 ~3f P [CR]
Response: /XCCAAA[CR]

Issue a Read WCR command to a Xicor X9241 at slave address 0x50.

Command: /X S ~50 ~90 ~R P [CR]
Response: /XCCAA~xx[CR]

‘(xx = 00...FF)

Issue an Increment Wiper command to a Xicor X9241 at slave address 0x50.

Command: /X S ~50 ~20 1 P [CR]
Response: /XCCAA[CR]

Issue an Decrement Wiper command to a Xicor X9241 at slave address 0x50.

Command: /X S ~50 ~20 0 P [CR]
Response: /XCCAA[CR]