Slave Operations
To Slave Transmit a message:
Enter data to be transmitted in the Slave Tx Message Bytes control by single
clicking. Binary data bytes are entered using a three character
Hex-Equivalent format (~00 ... ~FF), you may also type in ASCII text. These
bytes are automatically transmitted when a Slave Transmit Request is
received from a Master device.
To Slave Receive a message:
Data bytes received from a Master Transmitter are automatically displayed in
the Received Message window. Received binary data is displayed using a
three character Hex-Equivalent format (~00 ... ~FF). By selecting the Hex-
Display checkbox, the data is displayed as Hexadecimal data .
Uninstalling iPort Utility Pack
Click, Start | Programs | iPort Utility Pack | uninstall.