Installing the front bezel (pedestal only), Figure 10. installing the front bezel – Intel SC5400 User Manual
Page 37
Intel® Server Chassis SC5400 User’s Guide
19
Installing the Front Bezel (Pedestal Only)
Caution: This step applies to a pedestal configuration chassis only. For instructions on installing a
bezel in a rack-mount configuration, refer to the Rack Conversion kit Installation Guide:
Intel
®
Server Chassis SC5400.
1. Open the outer bezel door of the bezel assembly (see letter “A” in the following
figure).
2. Remove the filler panels that correspond to installed devices (see letter “B”).
3. Close the outer bezel door (see letter “C”).
4. Fit the right edge of the bezel assembly against the right side of the chassis.
5. Engage the plastic bezel hooks (see letter “D”) into the raised metal slots at the
chassis edge.
6. Rotate the bezel assembly toward the chassis.
7. Latch the two plastic tabs (see letter “E”) on the left side of the bezel assembly to
the chassis.
Figure 10. Installing the Front Bezel
AF000558