IBM 6274 User Manual
Page 60

46
User Guide
section, always begin by following the suggested action for the first error message
that is displayed. Note that, in these tables, x can be any alphanumeric character.
Code
Description
Action
151
Real time clock failure
Go to “Starting and using the IBM
Setup Utility program” on page 27, and
follow the instructions to reset the time
and date.
If the problem persists, have the
computer serviced.
161
Defective CMOS Battery
Replace the battery. See “Replacing the
battery” on page 66.
162
A change in the device
configuration occurred
Go to “Starting and using the IBM
Setup Utility program” on page 27, and
follow the instructions to load the
Default Settings.
If the problem persists, have the
computer serviced.
163
Clock not updating
Go to “Starting and using the IBM
Setup Utility program” on page 27, and
follow the instructions to reset the time
and date.
If the problem persists, have the
computer serviced.
164
CMOS RAM memory size does not
match
This is expected if you have removed
memory. Otherwise,
Go to “Running the IBM Enhanced
Diagnostics program” on page 66 for
instructions on running memory
diagnostics.
301
Keyboard error
1.
Make sure the keyboard is properly
connected.
2.
If the keyboard is properly
connected, have the computer
serviced.