4-08-43

Electrical Requirements for Electric
Models

Refer to Table 6.

NOTE: Minimum wire sizes are obtained from

Canadian Electrical Code for 75°C Conductors

and are intended for use as a guideline only.

Electrical connections should be made only by a

qualified electrical contractor in accordance with

all applicable local and national requirements.

NOTE: Electrical specifications below are subject

to change without notice. Always refer to product

serial plate for most current specifications of

product being installed.

NOTE: Connect to individual branch circuit.

NOTE: 3 Phase Only – Each tumbler must be

connected to its own individual branch circuit

breaker, not fuses, to avoid the possibility of “single

phasing” and causing premature failure of the

motor(s).

For 21 kW T30 Electric Models:

Table 6

Serial Plate

Voltage

Terminal Block

Connections

Required

Current

(Amps)

Recommended

Breaker Rating

(Amps)

Breaker

Poles

Recommended

Minimum

Conductor Size

(AWG [mm

2

])

200-208V/60Hz/3ph*

L1, L2, L3,

and ground

62**

80

3

4 (21.2)

200V/50Hz/3ph*

L1, L2, L3,

and ground

60**

80

3

4 (21.2)

230-240V/50Hz/3ph*

L1, L2, L3,

and ground

55**

70

3

4 (21.2)

240V/60Hz/3ph*

L1, L2, L3,

and ground

54**

70

3

4 (21.2)

380V/50 or 60Hz/3ph*

L1, L2, L3,

and ground

33**

45

3

8 (8.37)

400-415V/50Hz/3ph*

L1, L2, L3,

and ground

31**

40

3

8 (8.37)

460-480V/60Hz/3ph*

L1, L2, L3,

and ground

27**

35

3

8 (8.37)

* These serial plate voltages are only options available on the T30 electric models. Current (Amp) is for one pocket only.