Figure 5, Table 3 to – IPSO T30 User Manual
Page 18
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Tumblers – T30 and T45
4-08-43
17
Figure 5
TMB2018N
1
NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, the opening
MUST be sized per local codes.
2
Outlet Duct Diameter
3
45° Typical
1
2
3
L
K
J
I
L
K
J
I
CONTINUE
TO A
CONTINUE
TO A
TWO MANIFOLD ASSEMBLIES
Duct
Station
T30
T45
8 in. (203 mm) Duct
10 in. (254 mm) Duct
A
12 in. (305 mm)
15 in. (381 mm)
B
17 in. (432 mm)
22 in. (559 mm)
C
22 in. (559 mm)
26 in. (660 mm)
D
25 in. (635 mm)
30 in. (762 mm)
E
27 in. (686 mm)
34 in. (864 mm)
F
30 in. (762 mm)
37 in. (940 mm)
G
33 in. (838 mm)
40 in. (1016 mm)
H
34 in. (864 mm)
43 in. (1092 mm)
I
37 in. (940 mm)
46 in. (1168 mm)
J
39 in. (991 mm)
47 in. (1194 mm)
K
40 in. (1016 mm)
50 in. (1270 mm)
L
43 in. (1092 mm)
51 in. (1295 mm)
Table 3