beautypg.com

Cording to figure 4, 1 m). refer to table 2 or – IPSO T30 User Manual

Page 17

background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Tumblers – T30 and T45

16

4-08-43

Figure 4

TMB2019N

1

NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, the opening
MUST be sized per local codes.

2

Outlet Duct Diameter

3

45° Typical

L

K

J

I

H

G

F

E

D

C

B

A

3

1

2

ONE MANIFOLD ASSEMBLY

Duct

Station

T30

T45

8 in. (203 mm) Duct

10 in. (254 mm) Duct

A

8 in. (203 mm)

10 in. (254 mm)

B

12 in. (305 mm)

15 in. (381 mm)

C

15 in. (381 mm)

18 in. (457 mm)

D

17 in. (432 mm)

21 in. (533 mm)

E

19 in. (483 mm)

24 in. (610 mm)

F

21 in. (533 mm)

26 in. (660 mm)

G

23 in. (584 mm)

28 in. (711 mm)

H

24 in. (610 mm)

30 in. (762 mm)

I

26 in. (660 mm)

32 in. (813 mm)

J

27 in. (686 mm)

33 in. (838 mm)

K

28 in. (711 mm)

35 in. (889 mm)

L

30 in. (762 mm)

36 in. (914 mm)

Table 2

This manual is related to the following products: